| LED Status | Error Description | Manual Solution (Page 22-24) | | :--- | :--- | :--- | | | Overvoltage (>30V DC) | Reduce voltage immediately. Unit may be damaged. | | "In 1" flashing red | Channel 1 stuck closed | Replace the E-stop button or safety switch. | | "In 2" off, "In 1" on | Mismatched input timing | Inputs must change state within 0.5 seconds of each other. Check wiring symmetry. | | "Out" flashing yellow | Feedback loop broken | Check the auxiliary contacts on your external contactors. | | All LEDs cycle | Internal watchdog fault | Cycle power. If persists, replace the unit (internal CPU error). |

Close all safety gates and pull out all E-stop buttons. The "In 1" and "In 2" LEDs should turn green. Xtra Safe Kt 82001 Manual

If you have lost your physical copy, Xtra Safe provides digital backups. Remember: In safety engineering, guessing is not a strategy. Always consult the manual. | LED Status | Error Description | Manual